<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-20 02-01-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
6.6 kHz 4.3 kHz -17 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 71 kHz 10060 0,3777
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,9 dBr 7,22 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 2:01, 20.05.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (56 dBuV) Max at: 71 kHz MIN: 11 kHz % above 75 kHz: 0,3777 Acquired: 2025/05/20 2:00:26 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,1 dBr MIN: 5,9 dBr AVE: 7,22 dBr % above 10,2 dBr: 0,0 Last value: 7,2 dBr (2025/05/20 2:00:26) Station: 96.90 MHz, signal: 5/5 (56 dBuV) 01:54 01:55 01:56 01:57 01:58 01:59 02:00 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality